Steadypower.com has immediate Kohler Rental Power solutions.


Renting a generator can provide immediate solutions for power shortages, outages, or special needs.

     

Rental applications:

  • Construction/Mining/Drilling: Construction sites, mining and drilling operations depend on power tools. To meet aggressive deadlines, power is often required 24 hours a day. In many cases utility power is not available and small portable generators lack the necessary kW output and fuel capabilities to meet these requirements. In this case, mobile rental generators provide the necessary reliable power to keep the job site running.

  • Utility: Public utilities, such as water plants, wastewater treatment facilities, food distribution, and transportation lines need to maintain constant operation. Electrical failures at control stations as well as routine maintenance shutdowns create a need for reliable temporary power. With rental generators power can be maintained preventing interruption of necessary services.

  • Government: National airports, military installations, and other government facilities often require temporary power for both planned and emergency applications. Facility modernization and expansion are continually taking place to keep up with technical innovation and advances. Rental generators can meet the increased power capacity to keep operations running.

  • Municipal: Court houses, police stations, jails, schools, fire departments and municipal buildings in many cases do not have emergency standby power systems. When damage results from severe weather or utility blackouts/brownouts, rental generators can provide reliable power allowing crucial services and operations to be maintained.

  • Special events/Entertainment: Special events and entertainment demand additional electrical load requirements for specific periods of time. Whether it's a corporate picnic, a rock concert, special network sporting events, or an on-location movie production, rental generators are designed and engineered with the flexibility to meet unique customer requirements. With sound attenuated housings power can be supplied without disrupting the event.

  • Manufacturing & Processing: Large industrial manufacturing facilities and chemical/petrochemical plants need constant power. Regularly scheduled maintenance shutdowns and emergencies from plant power failures require immediate power solutions. Rental generators can meet these needs. Many times, smaller manufacturing firms do not have a source of standby power. When emergencies arise, rental generators can assure the continued operation of these facilities

  • Healthcare: Hospitals and rehabilitation centers often already have emergency standby power. However, temporary power is often needed during powerhouse inspections, maintenance shutdowns, expansion projects, or other events such as broadcasting medical procedures for education.

[ TOP ]

Generator set features:

  • Durable aluminum sound attenuated (20-180kW) or aluminum enclosure (300 kW)
  • Electrical power panel with single-phase receptacles (20-180 kW) and line circuit breaker
  • Internal/External fuel tanks with low fuel shutdown
  • Lockable generator output 3-position selector switch installed and wired
  • Single-point lifting eye and eight position tie down and lift rings (50-180 kW)

Trailer features:

  • Fire extinguisher and work lights with time
  • Interchangeable 2 5/16 inch ball or pintle ring/Lunette eye configuration (50-180 kW)
  • Leveling jack, 10,000 pound rated (20-180 kW)
  • Lockable sound attenuated doors and tool box (20-180 kW)
  • Running lights with wiring harness/connector (20-180 kW) or DOT 7-way socket (300 kW)
  • Spare tire and lug nut wrench (50-300kW)
  • Surge or electric brake system

Engine Features:

  • Battery, battery rack, and battery cables
  • Battery charger (50-300 kW)
  • Electronic governor
  • Engine block heater (50-300 kW)
  • Exhaust silencer with flex exhaust connector


Accessories:

  • Power Cables with Quick Connectors
  • Power Distribution Panels
  • Automatic Transfer Switches
  • Auxiliary Fuel tanks
  • Mobile Load Banks
Trailer-Mounted Generator Set Specifications
Generator Set Model
Length1
Width2
Height3
Trailer Weight
Generator Set and Enclosure Weight
Gross Weight 4
Fuel Tank(s) Internal/External
mm (in.)
mm (in.)
mm (in.)
kg (lbs.)
kg (lbs.)
kg (lbs.)
U.S. L (gals.)
20RCOZN 3683 (145) 1880 (74) 2076 (82) 308 (680) 744 (1640) 1052 (2320) 95(25)
50ROZDN 4724 (186) 2413 (95) 2515 (99) 590 (1300) 2214 (4880) 2803 (6180) 182 (48)/587 (155)
100REOZDN 5239 (206) 2413 (95) 3073 (121) 617 (1360) 2767 (6100) 3384 (7460) 257 (68)/587 (155)
180ROZDN 5239 (206) 2413 (95) 3073 (121) 658 (1450) 3697 (8150) 4355 (9600) 257 (68)/587 (155)

1
Length includes trailer tongue.
2 Width includes trailer fenders.
3 Height includes generator set weather housing.
4 Gross weight includes trailer, generator set, weather housing, and fuel tank(s) with no fuel.

Generator Set Specifications
Generator Set Model Engine Generator Model Standby Rating
240 Volt, 1 Ph 208 Volt, 3 Ph 480 Volt, 3 Ph 600 Volt, 3 Ph
Amps kW/kVA Amps kW/kVA Amps kW/kVA Amps kW/kVA
20RCOZN Yanmar 4J7 68.8 16.5/16.5 69.4 20.0/25.0 30.1 20.0/25.0 N/A N/A
50ROZJN John Deere 4P8 204 49/49 191 55/69 83 55/69 N/A N/A
100REOZJN John Deere 4S9 333 80/80 347 100/125 158 105/131 N/A N/A
180ROZJN John Deere 4UA7 542 130/130 625 180/225 271 180/225 210 175/219

Generator Set Model Engine Generator Model Fuel Consumption Lph (gph) Sound Level dBA with No Load
      25% Load 55% Load 75% Load 100% Load @ 21 ft. (7m)
20RCOZN
Yanmar
4J7
2.30
0.6
3.40
0.9
4.80
1.3
6.30
1.7
58
50ROZJN
John Deere
4P8
6.10
1.6
8.70
2.3
12.10
3.2
16.30
4.3
60
100REOZJN
John Deere
4S9
9.80
2.6
16.70
4.4
23.10
6.1
29.90
7.9
62
180ROZJN
John Deere
4UA7
15.90
4.2
26.50
7.0
38.60
10.2
51.90
13.7
64
N/A Not available
 
 
 
 
 
 
 
 
 
 
 

NOTES: Other voltages are available using selector switch and voltage adjustment potentiometer/switch. See the available voltage choices below. The 600-volt models do not have selector switches and are not reconnectible. See the respective spec sheets for specifications not shown. See the Additional Literature table for generator set and controller spec sheet part numbers.

[ TOP ]

     

Trailer-Mounted Generator Set Specifications
Generator Set Model
Length
Width
Height
Generator Set and Enclosure Weight
Gross Weight*
Fuel Tank(s) Internal/External
  mm (in.) mm (in.) mm (in.) kg (lbs.) kg (lbs.) U.S. L (gals.)
300REOZDN
8534
(336)
2438 (96)
2896 (114)
3032 (6684) 9072 (20000) 2120 560
400REOZD-4N
8534
(336)
3461 (7630) 9072 (20000) 2839 750
600ROZD-4N
8534
(336)
4750 (10472) 9979 (22000) 2839 750
800ROZD-4N
12192
(480)
5930 (13073) 16783 (37000) 3785 1000
1000ROZD-4N
12192
(480)
7200 (15873) 16783 (37000) 3785 1000
1500ROZD-4N
12192
(480)
13691 (30184) 25855 (57000) 3785 1000
1750ROZD-4N
12192
(480)
15649 (34500) 27216 (60000) 3785 1000
2000ROZD-4N
12192
(480)
15876 (35000) 27669 (61000) 3785 1000

* Gross weight includes trailer, generator set, and fuel tank(s) with no fuel.

Generator Set Specifications
Generator Set Model Engine Generator Model         Sound Level dBA with No Load
      25% Load 50% Load 75% Load 100% Load @ 7 m (23 ft.)
300REOZDN DDC Series 60 4UA13 22.7 (6.0) 42.0 (11.1) 61.7 (16.3) 82.5 (21.8) 72
400REOZD-4N DDC Series 60 5M4027 30.3 (8.0) 54.9 (14.5) 83.3 (22.0) 114.3 (30.2) 72
600ROZD-4N DDC Series 2000 5M4030 47.5 (12.6) 83.9 (22.2) 122.4 (32.3) 169.5 (44.8) 72
800ROZD-4N DDC Series 2000 5M4036 62.9 (16.6) 108.4 (28.6) 161.8 (42.7) 217.6 (57.5) 78
1000ROZD-4N DDC Series 2000 5M4044 77.5 (20.5) 138.9 (36.7) 202.3 (53.4) 277.1 (73.2) 78
1500ROZD-4N DDC Series 2000 7M4050 102.6 (27.2) 191.4 (50.6) 279.0 (73.6) 377.4 (99.7) 80
1750ROZD-4N DDC Series 4000 7M4052 133.2 (36.1) 229.8 (62.6) 327.6 (86.5) 435 (114.9) 82
2000ROZD-4N DDC Series 4000 7M4054 145.8 (38.6) 254.4 (67.2) 366.0 (96.7) 504 (133.2) 82

NOTES: Other voltages are available using selector swtich and voltage adjustment potentiometer/switch. See the available voltage choices below. The 600-volt models do not have selectro switches and are not reconnectible.
See the respective spec sheets for specifications not shown. See the Additional Literature table for generator set and controller spec sheet part numbers.
N/A--Not Available

Electrical Power Panel Specifications
      Voltage Selector Switch Models
Generator Model
Load Lug Connections
Load Lug Circuit Breakers, Amp
Available Selector Switch Voltages
Shore Power Electrical Service and Hook-up for Battery Charger and Block Heater
Remote Start Capability
300REOZDN (2) #4-500 MCM 1000(208-240 Volt) 500 (480 Volt) 120/208 V, 3 Ph, 120/240 V, 3 Ph 127/220 V, 3 Ph, 277/480 V, 3 Ph 240/416 V, 3 Ph, 220/380 V, 3 Ph 40 Amp/240 Volt Power Cord Required Yes
400REOZD-4N (5) #3-750 MCM 1400/600 120/208 V, 3 Ph, 120/240 V, 3 Ph 127/220 V, 3 Ph, 277/480 V, 3 Ph
600ROZD-4N (4) #3-600 MCM 1000 127/220 V, 3 Ph, 277/480 V, 3 Ph
800ROZD-4N (5) #3-500 MCM 1400
1000ROZD-4N (5) #3-750 MCM 1600
1500ROZD-4N (8) #3-750 MCM 2500
1750ROZD-4N (9) #3-750 MCM 3000
2000ROZD-4N (9) #3-750 MCM 3000
 
      600-Volt Models
Generator Model Load Lug Connections Load Lug Circuit Breakers, Amp Available Voltages Shore Power Electrical Service and Hook-up for Battery Charger and Block Heater Remote Start Capability
300REOZDN (2) #4-400 MCM 500 600 Volt, 3 Phase only 40 Amp/240 Volt Power Cord Required Yes
600ROZD-4N (3) 3/0-500 MCM 800
1000ROZD-4N (4) 3/0-600 MCM 1200

[ TOP ]

Other Sizes and Configurations

KW

Available Voltages

HZ

Trailer

Fuel Capacity

Fuel Consumption Gallons/Hour

Sound Attenuated

15

A, B, D

60/50

Single

40

1.4

Yes

25

A, B, C, D

60/50

Single

80

2.1

No

40

A, B, C, D

60/50

Tandem

100

3

Yes

50

A, B, C, D

60/50

Tandem

50

4.3

No

100

A, B, C, D

60/50

Tandem

100

7.4

Yes

150

A, B, D

60/50

Tandem

200

11.4

No

230

A

60/50

Semi

500

18

No

275

A, B, C, D

60/50

Semi

300

23

No

500

A, B

60/50

Semi

1100

40

No

1250

A

60/50

Semi

1100

90

Yes

 

All Units Diesel Powered

 

A = 277/480 Three Phase

B = 120/208 Three Phase

C = 120/240 Three Phase

D = 120/240 Single Phase

[ TOP ]

Useful Electrical Formulas

To Obtain:

Single Phase*

Three Phase*

Kilowatts

V x l x pf
1000

1.732 x V x l x pf
1000

kV-A

V x l
1000

1.732 x V x l
1000

Horsepower required when generator kW is unknown (if generator efficiency unknown, use 0.85 x hp)

kW
0.746 x Efficiency
(Generator)

kW
0.746 x Efficiency
(Generator)

kW input when motor hp known (if motor efficiency unknown, use 0.85 x hp)

hp x 0.746
Efficiency (Motor)

hp x 0.746
Efficiency (Motor)

Amperes when motor hp known

hp x 0.746
V x pf x Efficiency

hp x 0.746
1.732 x V x pf x Efficiency

Amperes when kW known

kW x 1000
V x pf

kW x 1000
1.732 x V x pf

Amperes when kV-A known

kV-A x 1000
V

kV-A x 1000
1.732 x V

 

* Alternating Current



[ TOP ]

kV-A/kW Amperage Chart (80% Power Factor)

kV-A

kW

208V

240V

380V

480V

18.7

15.0

52.0

45.0

28.8

22.5

25.0
20.0
69.5
60.2
38.4
30.1
31.3
25.0
87.0
75.5
48.0
37.8

37.5

30.0

104.0

90.3

57.6

45.2

50.0
40.0
139.0
120.0
77.0
60.0
62.5
50.0
173.0
152.0
96.0
76.0

75.0

60.0

208.0

181.0

115.0

91.0

93.8
75.0
261.0
226.0
143.0
113.0
100.0
80.0
278.0
240.0
154.0
120.0

125.0

100.0

347.0

301.0

192.0

150.0

156.0
125.0
433.0
375.0
240.0
188.0
187.0
150.0
520.0
450.0
288.0
225.0

219.0

175.0

608.0

527.0

335.0

264.0

250.0
200.0
694.0
601.0
384.0
301.0
312.0
250.0
866.0
751.0
480.0
376.0

375.0

300.0

1040.0

903.0

576.0

451.0

438.0
350.0
1220.0
1053.0
672.0
527.0
500.0
400.0
1390.0
1203.0
770.0
602.0

625.0

500.0

1735.0

1504.0

960.0

752.0

750.0
600.0
2080.0
1803.0
1150.0
902.0
875.0
700.0
2430.0
2104.0
1344.0
1052.0

1000.0

800.0

2780.0

2405.0

1540.0

1203.0

1125.0
900.0
3120.0
2709.0
1730.0
1354.0
1250.0
1000.0
3470.0
3009.0
1920.0
1504.0

1563.0

1250.0

4350.0

3765.0

2400.0

1885.0

1875.0
1500.0
5205.0
4520.0
2880.0
2260.0
2188.0
1750.0
 
5280.0
3350.0
2640.0

2500.0

2000.0

 

6020.0

3840.0

3015.0

[ TOP ]


For larger or custom system requirements including industrial, commercial, military, and all three-phase applications, please contact us for sizing and pricing information. Our experienced staff can help you determine and fill your special requirements.


 


3300 Jefferson Ave Grand Rapids, MI. 49548
Call Toll Free: 888-331-5344
Fax: 616-452-1337
E-mail: customerservice@steadypower.com