| Steadypower.com
has immediate Kohler Rental Power solutions.
Renting
a generator can provide immediate solutions for power
shortages, outages, or special needs.

Rental
applications:
- Construction/Mining/Drilling:
Construction sites, mining and drilling operations depend
on power tools. To meet aggressive deadlines, power
is often required 24 hours a day. In many cases utility
power is not available and small portable generators
lack the necessary kW output and fuel capabilities to
meet these requirements. In this case, mobile rental
generators provide the necessary reliable power to keep
the job site running.
- Utility:
Public utilities, such as
water plants, wastewater treatment facilities, food
distribution, and transportation lines need to maintain
constant operation. Electrical failures at control stations
as well as routine maintenance shutdowns create a need
for reliable temporary power. With rental generators
power can be maintained preventing interruption of necessary
services.
- Government:
National airports, military installations, and other
government facilities often require temporary power
for both planned and emergency applications. Facility
modernization and expansion are continually taking place
to keep up with technical innovation and advances. Rental
generators can meet the increased power capacity to
keep operations running.
- Municipal:
Court houses, police stations, jails, schools, fire
departments and municipal buildings in many cases do
not have emergency standby power systems. When damage
results from severe weather or utility blackouts/brownouts,
rental generators can provide reliable power allowing
crucial services and operations to be maintained.
- Special
events/Entertainment: Special
events and entertainment demand additional electrical
load requirements for specific periods of time. Whether
it's a corporate picnic, a rock concert, special network
sporting events, or an on-location movie production,
rental generators are designed and engineered with the
flexibility to meet unique customer requirements. With
sound attenuated housings power can be supplied without
disrupting the event.
- Manufacturing
& Processing: Large industrial manufacturing
facilities and chemical/petrochemical plants need constant
power. Regularly scheduled maintenance shutdowns and
emergencies from plant power failures require immediate
power solutions. Rental generators can meet these needs.
Many times, smaller manufacturing firms do not have
a source of standby power. When emergencies arise, rental
generators can assure the continued operation of these
facilities
- Healthcare:
Hospitals and rehabilitation centers often already
have emergency standby power. However, temporary power
is often needed during powerhouse inspections, maintenance
shutdowns, expansion projects, or other events such
as broadcasting medical procedures for education.
[
TOP ]
Generator
set features:
- Durable
aluminum sound attenuated (20-180kW) or aluminum enclosure
(300 kW)
- Electrical
power panel with single-phase receptacles (20-180 kW)
and line circuit breaker
- Internal/External
fuel tanks with low fuel shutdown
- Lockable
generator output 3-position selector switch installed
and wired
- Single-point
lifting eye and eight position tie down and lift rings
(50-180 kW)
Trailer
features:
- Fire
extinguisher and work lights with time
- Interchangeable
2 5/16 inch ball or pintle ring/Lunette eye configuration
(50-180 kW)
- Leveling
jack, 10,000 pound rated (20-180 kW)
- Lockable
sound attenuated doors and tool box (20-180 kW)
- Running
lights with wiring harness/connector (20-180 kW) or
DOT 7-way socket (300 kW)
- Spare
tire and lug nut wrench (50-300kW)
- Surge
or electric brake system
Engine
Features:
- Battery,
battery rack, and battery cables
- Battery
charger (50-300 kW)
- Electronic
governor
- Engine
block heater (50-300 kW)
- Exhaust
silencer with flex exhaust connector
Accessories:
- Power
Cables with Quick Connectors
- Power
Distribution Panels
- Automatic
Transfer Switches
- Auxiliary
Fuel tanks
- Mobile
Load Banks
| Trailer-Mounted
Generator Set Specifications |
| Generator
Set Model |
Length1 |
Width2 |
Height3 |
Trailer
Weight |
Generator
Set and Enclosure Weight |
Gross
Weight 4 |
Fuel
Tank(s) Internal/External |
| |
mm
(in.) |
mm
(in.) |
mm
(in.) |
kg
(lbs.) |
kg
(lbs.) |
kg
(lbs.) |
U.S.
L (gals.) |
| 20RCOZN |
3683 |
(145) |
1880 |
(74) |
2076 |
(82) |
308 |
(680) |
744 |
(1640) |
1052 |
(2320) |
95(25) |
| 50ROZDN |
4724 |
(186) |
2413 |
(95) |
2515 |
(99) |
590 |
(1300) |
2214 |
(4880) |
2803 |
(6180) |
182
(48)/587 (155) |
| 100REOZDN |
5239 |
(206) |
2413 |
(95) |
3073 |
(121) |
617 |
(1360) |
2767 |
(6100) |
3384 |
(7460) |
257
(68)/587 (155) |
| 180ROZDN |
5239 |
(206) |
2413 |
(95) |
3073 |
(121) |
658 |
(1450) |
3697 |
(8150) |
4355 |
(9600) |
257
(68)/587 (155) |
1 Length includes trailer tongue. |
| 2
Width includes trailer fenders. |
| 3
Height includes generator set weather housing.
|
| 4
Gross weight includes trailer, generator set, weather
housing, and fuel tank(s) with no fuel. |
| Generator
Set Specifications |
| Generator
Set Model |
Engine |
Generator
Model |
Standby
Rating |
| 240
Volt, 1 Ph |
208
Volt, 3 Ph |
480
Volt, 3 Ph |
600
Volt, 3 Ph |
| Amps |
kW/kVA |
Amps |
kW/kVA |
Amps |
kW/kVA |
Amps |
kW/kVA |
| 20RCOZN |
Yanmar |
4J7 |
68.8 |
16.5/16.5 |
69.4 |
20.0/25.0 |
30.1 |
20.0/25.0 |
N/A |
N/A |
| 50ROZJN |
John
Deere |
4P8 |
204 |
49/49 |
191 |
55/69 |
83 |
55/69 |
N/A |
N/A |
| 100REOZJN |
John
Deere |
4S9 |
333 |
80/80 |
347 |
100/125 |
158 |
105/131 |
N/A |
N/A |
| 180ROZJN |
John
Deere |
4UA7 |
542 |
130/130 |
625 |
180/225 |
271 |
180/225 |
210 |
175/219 |
| Generator
Set Model |
Engine |
Generator
Model |
Fuel
Consumption Lph (gph) |
Sound
Level dBA with No Load |
| |
|
|
25% Load |
55% Load |
75% Load |
100%
Load |
@
21 ft. (7m) |
| 20RCOZN |
Yanmar |
4J7 |
2.30 |
0.6 |
3.40 |
0.9 |
4.80 |
1.3 |
6.30 |
1.7 |
58 |
| 50ROZJN |
John
Deere |
4P8 |
6.10 |
1.6 |
8.70 |
2.3 |
12.10 |
3.2 |
16.30 |
4.3 |
60 |
| 100REOZJN |
John
Deere |
4S9 |
9.80 |
2.6 |
16.70 |
4.4 |
23.10 |
6.1 |
29.90 |
7.9 |
62 |
| 180ROZJN |
John
Deere |
4UA7 |
15.90 |
4.2 |
26.50 |
7.0 |
38.60 |
10.2 |
51.90 |
13.7 |
64 |
| N/A
Not available |
|
|
|
|
|
|
|
|
|
|
|
NOTES: Other voltages are available using selector
switch and voltage adjustment potentiometer/switch.
See the available voltage choices below. The 600-volt
models do not have selector switches and are not reconnectible.
See the respective spec sheets for specifications
not shown. See the Additional Literature table for
generator set and controller spec sheet part numbers. |
[
TOP ]

| Trailer-Mounted
Generator Set Specifications |
| Generator
Set Model |
Length |
Width |
Height |
Generator
Set and Enclosure Weight |
Gross
Weight* |
Fuel
Tank(s) Internal/External |
| |
mm
(in.) |
mm
(in.) |
mm
(in.) |
kg
(lbs.) |
kg (lbs.) |
U.S.
L (gals.) |
| 300REOZDN |
8534 |
(336) |
2438 (96) |
2896 (114) |
3032 |
(6684) |
9072 |
(20000) |
2120 |
560 |
| 400REOZD-4N |
8534 |
(336) |
3461 |
(7630) |
9072 |
(20000) |
2839 |
750 |
| 600ROZD-4N |
8534 |
(336) |
4750 |
(10472) |
9979 |
(22000) |
2839 |
750 |
| 800ROZD-4N |
12192 |
(480) |
5930 |
(13073) |
16783 |
(37000) |
3785 |
1000 |
| 1000ROZD-4N |
12192 |
(480) |
7200 |
(15873) |
16783 |
(37000) |
3785 |
1000 |
| 1500ROZD-4N |
12192 |
(480) |
13691 |
(30184) |
25855 |
(57000) |
3785 |
1000 |
| 1750ROZD-4N |
12192 |
(480) |
15649 |
(34500) |
27216 |
(60000) |
3785 |
1000 |
| 2000ROZD-4N |
12192 |
(480) |
15876 |
(35000) |
27669 |
(61000) |
3785 |
1000 |
* Gross weight includes trailer, generator set, and
fuel tank(s) with no fuel. |
|
Generator
Set Specifications |
| Generator
Set Model |
Engine |
Generator
Model |
|
|
|
|
Sound
Level dBA with No Load |
| |
|
|
25%
Load |
50%
Load |
75%
Load |
100%
Load |
@
7 m (23 ft.) |
| 300REOZDN |
DDC
Series 60 |
4UA13 |
22.7 |
(6.0) |
42.0 |
(11.1) |
61.7 |
(16.3) |
82.5 |
(21.8) |
72 |
| 400REOZD-4N |
DDC
Series 60 |
5M4027 |
30.3 |
(8.0) |
54.9 |
(14.5) |
83.3 |
(22.0) |
114.3 |
(30.2) |
72 |
| 600ROZD-4N |
DDC
Series 2000 |
5M4030 |
47.5 |
(12.6) |
83.9 |
(22.2) |
122.4 |
(32.3) |
169.5 |
(44.8) |
72 |
| 800ROZD-4N |
DDC
Series 2000 |
5M4036 |
62.9 |
(16.6) |
108.4 |
(28.6) |
161.8 |
(42.7) |
217.6 |
(57.5) |
78 |
| 1000ROZD-4N |
DDC
Series 2000 |
5M4044 |
77.5 |
(20.5) |
138.9 |
(36.7) |
202.3 |
(53.4) |
277.1 |
(73.2) |
78 |
| 1500ROZD-4N |
DDC
Series 2000 |
7M4050 |
102.6 |
(27.2) |
191.4 |
(50.6) |
279.0 |
(73.6) |
377.4 |
(99.7) |
80 |
| 1750ROZD-4N |
DDC
Series 4000 |
7M4052 |
133.2 |
(36.1) |
229.8 |
(62.6) |
327.6 |
(86.5) |
435 |
(114.9) |
82 |
| 2000ROZD-4N |
DDC
Series 4000 |
7M4054 |
145.8 |
(38.6) |
254.4 |
(67.2) |
366.0 |
(96.7) |
504 |
(133.2) |
82 |
NOTES: Other voltages are available using selector
swtich and voltage adjustment potentiometer/switch.
See the available voltage choices below. The 600-volt
models do not have selectro switches and are not reconnectible. |
| See
the respective spec sheets for specifications not
shown. See the Additional Literature table for generator
set and controller spec sheet part numbers. |
| N/A--Not
Available |
|
Electrical
Power Panel Specifications |
|
Voltage Selector Switch Models |
|
Generator
Model |
Load
Lug Connections |
Load
Lug Circuit Breakers, Amp |
Available
Selector Switch Voltages |
Shore
Power Electrical Service and Hook-up for Battery
Charger and Block Heater |
Remote
Start Capability |
| 300REOZDN |
(2)
#4-500 MCM |
1000(208-240
Volt) 500 (480 Volt) |
120/208
V, 3 Ph, 120/240 V, 3 Ph 127/220 V, 3 Ph, 277/480
V, 3 Ph 240/416 V, 3 Ph, 220/380 V, 3 Ph |
40
Amp/240 Volt Power Cord Required |
Yes |
| 400REOZD-4N |
(5)
#3-750 MCM |
1400/600 |
120/208
V, 3 Ph, 120/240 V, 3 Ph 127/220 V, 3 Ph, 277/480
V, 3 Ph |
| 600ROZD-4N |
(4)
#3-600 MCM |
1000 |
127/220
V, 3 Ph, 277/480 V, 3 Ph |
| 800ROZD-4N |
(5)
#3-500 MCM |
1400 |
| 1000ROZD-4N |
(5)
#3-750 MCM |
1600 |
| 1500ROZD-4N |
(8)
#3-750 MCM |
2500 |
| 1750ROZD-4N |
(9)
#3-750 MCM |
3000 |
| 2000ROZD-4N |
(9)
#3-750 MCM |
3000 |
| |
|
600-Volt Models |
| Generator
Model |
Load
Lug Connections |
Load
Lug Circuit Breakers, Amp |
Available
Voltages |
Shore
Power Electrical Service and Hook-up for Battery Charger
and Block Heater |
Remote
Start Capability |
| 300REOZDN |
(2)
#4-400 MCM |
500 |
600
Volt, 3 Phase only |
40 Amp/240 Volt Power Cord Required |
Yes |
| 600ROZD-4N |
(3)
3/0-500 MCM |
800 |
| 1000ROZD-4N |
(4)
3/0-600 MCM |
1200 |
[
TOP ]
|
Other
Sizes and Configurations |
|
KW
|
Available
Voltages |
HZ
|
Trailer
|
Fuel
Capacity |
Fuel
Consumption Gallons/Hour |
Sound
Attenuated |
| 15
|
A,
B, D |
60/50 |
Single |
40 |
1.4 |
Yes |
| 25
|
A,
B, C, D |
60/50 |
Single |
80 |
2.1 |
No |
| 40
|
A,
B, C, D |
60/50 |
Tandem |
100 |
3 |
Yes |
| 50
|
A,
B, C, D |
60/50 |
Tandem |
50 |
4.3 |
No |
| 100
|
A,
B, C, D |
60/50 |
Tandem |
100 |
7.4 |
Yes |
| 150
|
A,
B, D |
60/50 |
Tandem |
200 |
11.4 |
No |
| 230
|
A
|
60/50 |
Semi |
500 |
18 |
No |
| 275
|
A,
B, C, D |
60/50 |
Semi |
300 |
23 |
No |
| 500
|
A,
B |
60/50 |
Semi |
1100 |
40 |
No |
| 1250
|
A
|
60/50 |
Semi |
1100 |
90 |
Yes |
| |
| All
Units Diesel Powered |
|
|
| A
= 277/480 Three Phase |
| B
= 120/208 Three Phase |
| C
= 120/240 Three Phase |
| D
= 120/240 Single Phase |
[
TOP ]
|
Useful
Electrical Formulas |
|
To
Obtain: |
Single
Phase* |
Three
Phase* |
|
Kilowatts |
V x l x pf
1000 |
1.732 x V x l x pf
1000 |
|
kV-A |
V x l
1000 |
1.732 x V x l
1000 |
|
Horsepower
required when generator kW is unknown (if generator
efficiency unknown, use 0.85 x hp) |
kW
0.746 x Efficiency
(Generator) |
kW
0.746 x Efficiency
(Generator) |
|
kW
input when motor hp known (if motor efficiency unknown,
use 0.85 x hp) |
hp x 0.746
Efficiency (Motor) |
hp x 0.746
Efficiency (Motor) |
|
Amperes
when motor hp known |
hp x 0.746
V x pf x Efficiency |
hp x 0.746
1.732 x V x pf x Efficiency |
|
Amperes
when kW known |
kW x 1000
V x pf |
kW x 1000
1.732 x V x pf |
|
Amperes
when kV-A known |
kV-A x 1000
V |
kV-A x 1000
1.732 x V |
| |
| *
Alternating Current |
[ TOP ]
| kV-A/kW
Amperage Chart (80% Power Factor) |
|
kV-A
|
kW
| |