Simplex Nautilus Water Cooled Load Bank (250 kW)

  • Image 1
  • Image 2
  • Image 3
  • Image 4
  • Image 5
Call with Options for Price Quote: 1-888-331-5344
900.00 LBS

Bookmark and Share

The Simplex Nautilus Water-Cooled Resistive Load Bank is designed expressly for data-center chiller commissioning and testing applications. The Nautilus is fully networkable for control of single or multiple units from a remote station.


  • Infinite Power and Water Flow Control: For precise temperature rise setting versus applied power. Using a PLC with touchscreen HMI, integrated with temperature sensors and flow transducers and controlling an electrically operated water proportioning valve, the Nautilus allows the operator to select precise power levels, versus water temperature rise versus water flow rates. Power level is infinitely controllable over a 0-250kw range.
  • Completely Self-contained, Free-standing Unit: Includes all resistive load elements, load control, load element branch circuit fuse protection, main load bus and terminals, valves and fittings, control power supply, malfunction detection system.
  • Control System: PLC control with 8-inch color TFT touchscreen HMI. Screen is configured for local or remote operation. Remote requires 120v power source.
  • Control Function: Master control on-off button; keypad entry of load values, apply and remove buttons; controller calculates reduced voltage load values automatically, applying actual requested load value for the applied voltage up to the reduced voltage capacity of the load bank. Water Flow Control: Either full on or thermostatic control. Thermostatic control is either manual or to a temperature rise preset. Operator interface is a screen based vernier valve control with displays of valve position, flow rate, temp in, temp out, temp rise. Automatic thermostatic control allows operator to enter value of temp rise. Controller then adjusts flow rate to maintain that rise. Controller inhibits over temperature, greater than 180°F outlet temp. Displays: AC 3-phase voltage and current, frequency, kilowatts. Alarms: high outlet temp, low flow, high pressure Messages: normal operation, valve open, valve closed. Water Flow Control Messages: water inlet temp, water outlet temp, overall temp rise, main manifold water flow rate, valve position in percent of open.
  • Load Cell: 1 x 250 kW load, consisting of heavy-gauge, steel housing, load elements, control valves and sensors as described below
  • Load Elements: Immersion type, tubular construction, stainless steel or Incolloy sheathed, chromium-alloy conductor. Screw-plug mounting.
  • Water Flow Control: Equipped with main inlet and outlet shutoff ball valves, pressure relief valve. Motorized gate valve on inlet for water flow control.
  • System Protections: Sensors: Protection for High water temperature; Low water flow; High pressure. Alarm and shutdown upon failure detection.
  • Sensors: Main manifold flow transducer, 4-20mA; inlet water temp thermocouple, exhaust water temp thermocouple; cell pressure.
  • Element Circuit Protection: Branch circuit fuses, each 50 kW branch circuit or each step.
  • Load Control: Triac and Branch circuit contactors, each 25 kw or 50 kW circuit.
  • Control Power: External, via power inlet and power cord to 120v 15A outlet.
  • Power Connection: Cam-Type connectors, 1 x 4/0 (400A) per phase and 1 x ground. Bulk-head mount connectors installed on front.
  • Connections: Control Wiring: 90°C, color-coded and numbered; Power Wiring: 150°C insulated; color-coded and numbered, XLP insulation.
  • Enclosure: Environmental type 1 freestanding, indoor, portable enclosure. Aluminum frame clad with aluminum panels and doors. Front power connections. Rear water connections. Casters, forklift pads, lifting eyes. Powder coated white cabinet, blue doors.


Nautilus Brochure

Nautilus Manual


  • Software for control from a Windows- based PC, for data acquisition, and for full testing automation.
Max Capacity:
250 kW
Frequency :
60 Hz
Voltage :
480V AC, 3-phase, 3-wire
Load Steps:
Infinitely variable via digital control
Control Power:
External, via power inlet and power cord to 120v 15A outlet
Fresh water
Coolant Requirements:
Nominal 125 GPM supply yields approx. 12.5°F rise at full power; Flow rate is infinitely variable to a max temp rise not to exceed 180°F outlet - KW = GPM x Temp. Rise (F) x .16; GPM = KW / (Temp. Rise x .16); Temp. Rise (F) = KW / (GPM x .16)
Ambient Temperature:
Water Connection:
2-inch, water inlet and water outlet. Quick disconnect couplings, shutoff ball valves
Duty Cycle:
Enclosure :
Dimensions HxWxD (inches):
72 x 24 x 36
Approximately 1600 lbs full of water, 900 lbs dry
Limited Warranty:
12 Months