Loading... Please wait...
Steadypower.com
Mon-Fri, 8:00-4:30 EST - ORDER/HELP DESK
1-888-331-5344


Shop By Category


Click for the BBB Business Review of this Electric Equipment & Supplies - Retail in Grand Rapids MI
Online Payments
SSL

Gillette T4D-2000 Prime Generator (200kW)

  • Image 1
  • Image 2
Price:
Please Call for Low Discount Pricing
SKU:
T4D-2000
Weight:
7,892.00 LBS




Bookmark and Share

The Gillette T4D-2000 Prime Generator offers a Volvo diesel engine, three phase voltages, and up to 200 kW of continuous power.

T4D-2000 Models
Model Phase, Voltage,
Power Factor
Prime Rating
kW, kVA, Amps
 T4D-2000-3-2 3 Phase, 120/208V, 
0.8pf
200kW, 250kVA,
694A 
 T4D-2000-3-3 3 Phase, 120/240V,
0.8pf
200kW, 250kVA,
602A
 T4D-2000-3-4 3 Phase, 277/480V,
0.8pf 
200kW, 250kVA,
301A
T4D-2000-3-5 3 Phase, 127/220V,
0.8pf
200kW, 250kVA,
656A
T4D-2000-3-16 3 Phase, 346/600V,
0.8pf
200kW, 250kVA,
240A

FEATURES

  • Specifically engineered to handle the difficult conditions of remote oil and gas operations, as well as other off grid applications with continuous duty cycles.
  • All generator sets are USA prototype built and thoroughly tested. Production models are USA factory built and 100% load tested.
  • Solid state, frequency compensated voltage regulation is standard.
  • Electronic engine governor for precise isochronous frequency regulation.
  • Basler DGC-2020 digital controller offers an integrated gen-set control system for single gen-set applications, and includes generator metering, engine-generator protections, exercise timer, and expansion capabilities. Controller has stop-run-auto mode buttons, menu scroll buttons, and a backlit LCD display.
  • Heavy-duty circuit breaker is standard on all gen-sets.
  • Battery tray, cables, straps, and charger included.
  • UL-1446 certified.

ENCLOSURE OPTIONS

  • OPEN STYLE - No Enclosure: Gen-set must be placed within a weather protected area, un-inhabited by humans or animals, with proper ventilation. Silencer and flexible exhaust hose are not supplied , as installation requirements are not known. However, these two items are available as optional equipment.
  • LEVEL 2 - Aluminum Housing: Full weather protection and superior sound attenuation for specific low noise applications. Critical grade silencer is standard. Average sound level of 83 dBA at 23 ft.
Enclosure Dimensions and Weights
Enclosure Dimensions (inches)
L x W x H
Three Phase
Weight (lbs)
Open Style
132 x 52 x 65 5777
 Level 2
162 x 52 x 80 7547

DIESEL FUEL TANK OPTIONS

  • Feature double-walls and emergency vents. Designed for generator sub-base installation. UL-142 Certified.
  • Available in two sizes: 898 gallons (60 hour runtime) and 1796 gallons (120 hour runtime).
  • Further descriptions and tank options available here.
  • Generator can also be used with customer-supplied fuel tank.

DOWNLOADS

T4D-2000 Spec Sheet

T4D-2000 Open Drawing

T4D-2000 Enclosure Drawing

OPTIONS

  • Engine Coolant Heater
  • Starting Battery Heater Blankets
  • 10A Battery Charger Upgrade
  • 20A Battery Charger Upgrade
  • 750 CCA 12VDC Starting Battery
  • Paralleling Package
  • Camlock Connections Panel
  • Emergency Stop Switch - mounted in a NEMA 4X small enclosure, UL Listed, Suitable for remote locations
  • Emergency Stop Switch - mounted in a "Break Glass Station" NEMA 3R small enclosure, UL Listed, Suitable for remote locations
  • External Permanent Magnet Generator (PMG) for improved motor starting capabilities and un-interrupted excitation power
  • External Permanent Magnet Generator (PMG) with Digital Voltage Regulator (DVR) for improved motor starting capabilities, un-interrupted excitation power, and RMS sensing
  • Critical Grade Silencer Upgrade - for average sound level of 98 dBA at 23 ft with an Open Gen-Set (standard with Level 2 Enclosure)
  • Hospital Grade Silencer Upgrade
  • R7 Foam Insulation (4-5 dBA sound reduction)
  • Stainless Steel Enclosure
  • Generator Enclosure Lights
  • Liquid Containment Pan - installed under frame base
  • Spring Vibration Mounts
  • Motorized Dampers
  • Isolator Mounting Pads
  • Enclosure Space Heater
  • 18K Trailer with 450 Gallon Fuel Tank - designed for limited local or on-campus mobility
  • Controller Upgrades and Alarm Interfaces
  • Five Year Extended Warranty
Model:
T4D-2000
Prime Power Rating:
Varies - See Model Chart
Phase:
Three
Voltage:
Varies - See Model Chart
Voltage Regulation:
+/- 1/2%
Frequency:
60Hz
Power Factor:
0.8pf
Generator Type:
Stamford, 4 Pole, Brushless, Class H
Sound Level at 7m:
Varies - See Enclosure Options
Engine:
Volvo, EPA Tier 4 Final, 4-cycle, 6-cylinder, Turbo-After-Cooler, SCR Catalyst, DEF Tank
Engine Starting System:
Electric
Fuel Consumption:
18.7 gallons per hour at full load
Dimensions LxWxH (inches):
Varies - See Enclosure Chart
Approximate Weight:
Varies - See Enclosure Chart
Engine Warranty (Standby):
24 Months / 1000 hours
Generator Warranty (Standby):
24 Months / 1000 hours

Write your own product review

Product Reviews

This product hasn't received any reviews yet. Be the first to review this product!

Recently Viewed