 | PRO/TRAN Indoor Manual Transfer Switches These indoor surface mount
transfer switches are designed for fast installation in residential and commercial
applications. The 18-inch flexible conduit whip attaches easily to the load
center and all wires are clearly marked. Simply select the circuits needed in
an emergency and connect them to the Pro/Tran wire leads.
Pro/Tran
transfer switches feature a rugged powder-coated steel cabinet with six combination
1/2-inch and 3/4-inch knockouts, resettable branch rated circuit breakers and
non-defeatable (break-before-make) double-throw switches. Some models feature
exclusive Reliance wattmeters with accuracy of ± 3% throughout the entire
range.
All models with a power inlet on the front also include a cover
for the power inlet opening that facilitates hardwiring. All models without
a power inlet on the front include a covered opening that permits the installation
of a power inlet for cord connection directly to the transfer switch.
A wattmeter panel (WP7500)
is available for all models without meters (except models 15114A and 30114A).
The wattmeter panel includes an opening, with cover, for an optional power inlet.
|
|
 | PRO/TRAN Outdoor Manual Transfer Switches The Reliance Pro/Tran
R Series (NEMA 3R) transfer switches are ideal for outdoor installation
in residential and commercial applications. The gasketed steel cabinet is powder-coated,
with padlockable cover, and will accommodate the generator cord with the cover
closed. Included is 16-inch length of flexible non-metallic, liquid-tight conduit
with fittings. Simply mount the cabinet, attach the conduit and feed the clearly-marked
wires from the transfer switch into the load center. Then select the load center
circuits needed in an emergency and connect them to the wires leads from the
transfer switch. Each cabinet includes six combination 1/2-inch and 3/4-inch
knockouts, one on each side, two on the bottom and two on the back.
All Raintight Pro/Tran
transfer switches feature branch-circuit rated breakers, heavy-duty power inlet
and non-defeatable (break-before-make) double-throw switches. All 125/250V models
feature exclusive Reliance wattmeters with accuracy of ± 3% throughout
the entire range.
|
|
 | Panel/Link TRC Series Manual Transfer Panels (30-125A)
The Panel/Link TRC
offers circuit breaker combinations of 30A - 125A utility and generator. Interlinked
circuit breakers keep the generator isolated from the utility at all times,
even with the cover or deadfront removed. The TRC is service entrance rated
and may be used as a main panel or a sub-panel. The TRC features a heavy-duty
copper bus. The TRC is available in indoor and outdoor enclosures and has provision
for 12 to 20 branch circuits. The Panel/Link TRC is available
with and without power inlets or wattmeters.
|
|
 | Panel/Link TCA Series Manual Transfer Panels (60-125A) The Panel/Link TCA
offers circuit breaker combinations of 60A - 125A utility and 30A - 125A generator.
The interlinked circuit breakers keep the generator isolated from the utility
at all times, even with the deadfront removed. The TCA features a heavy-duty
copper bus. The TCA is suitable for service entrance and may be used as a main
panel for a single load or to feed a sub-panel. Available in indoor and outdoor
enclosures, the TCA has no provision for branch circuits breakers.
|
|
 | Panel/Link TTT Series 150 Amp Generator-Ready Load Centers The Panel/Link TTT
includes a 150A utility main breaker and a 30A - 125A generator breaker. The circuit
breakers are interlinked to keep the generator isolated from the utility at all
times, even with the deadfront removed. The TTT features a heavy-duty copper bus.
The TTT is suitable for service entrance and designed as a stand-alone, generator-ready
load center. Available in indoor and outdoor enclosures, the TTT has provision
for 26 branch circuits. Power inlet not included.
|
|
 | Panel/Link TTV Series 200 Amp Generator-Ready Load Centers The Panel/Link TTV
includes a 200A main circuit breaker interlinked with 30A - 125A generator circuit
breaker. The interlinked circuit breakers keep the generator isolated from the
utility at all times, even with the cover or deadfront removed. The TTV features
a heavy-duty copper bus. The TTV is suitable for service entrance and provides
for 36 branch circuits. Dual wattmeters, for balancing generator load, are optional.
|
|
 | Panel/Link TWB Series 150 Amp Manual Transfer Panels The Panel/Link TWB
includes a 150 main circuit breaker interlinked with a 30A - 125A generator breaker
feeding a heavy-duty copper bus with feed-through lugs. The interlinked circuit
breakers keep the generator isolated from the utility at all times, even with
the deadfront removed. The TWB is suitable for service entrance and may be used
as a main panel or feed-through to a sub-panel or main panel. The TWB has provision
for 4/8 branch circuits and is ideal for applications requiring the entire service
panel to be available for generator power.
|
|
 | Panel/Link TWB Series 200 Amp Manual Transfer Panels The Panel/Link TWB
includes a 200A main circuit breaker interlinked with a 30A - 125A generator breaker
feeding a heavy-duty copper bus with feed-through lugs. The interlinked circuit
breakers keep the generator isolated from the utility at all times, even with
the deadfront removed. The TWB is suitable for service entrance and may be used
as a main panel or feed-through to a sub-panel or main panel. The TWB has provision
for 4/8 branch circuits and is ideal for applications requiring the entire service
panel to be available for generator power.
|
|
|
|